The Honeywell BW GasAlertMicroClip XL is a small, clip-on 4 gas detector for hydrogen sulphide, carbon monoxide, oxygen and combustible gas. We supply the MicroClip XL and the wider BW MicroClip series, with the test gas and calibration to keep each unit in service.
| Gases and ranges | H2S 0 to 100 ppm, CO 0 to 500 ppm, O2 0 to 30.0%, combustible gas 0 to 100% LEL or 0 to 5.0% v/v methane |
|---|---|
| Battery | Rechargeable lithium polymer, 18 hours typical, recharges in less than 6 hours |
| Cold weather | Runtime for at least a 12 hour shift down to -20°C |
| Ingress protection | IP68, up to 45 minutes at a depth of 1.2 m |
| ATEX | II 1 G Ex ia IIC T4 Ga |
| IECEx | Ex ia IIC T4 Ga |
| Weight and size | 190 g, 11.3 x 6.0 x 3.2 cm |
| Operating temperature | -20°C to +50°C |
| Alarms | Visual, vibrating and audible (95 dB). Low, High, TWA, STEL and over limit |
| Docking | Compatible with the Honeywell IntelliDoX docking station for automated bump tests and calibration |
The MicroClip XL continuously monitors up to four gas hazards at once:
Size is the main reason. At 190 g, it clips to a collar or chest pocket and stays out of the way during a full shift. Honeywell describes it as easy to use with no expertise required: one button, simple icons on the display and a self-test of sensors, battery, circuits and alarms at start-up.
The rechargeable lithium polymer battery runs for 18 hours typical and recharges in under 6 hours. Honeywell guarantees runtime for at least a 12 hour shift down to -20°C without compromising LEL detection. The unit is rated IP68, which Honeywell states as up to 45 minutes at a depth of 1.2 m.
It is ATEX and IECEx approved Ex ia IIC T4 Ga. Our guide to ATEX zones explains what that marking means for hazardous areas. For entry into tanks, pits and chambers, see our page on confined space gas monitors.
The MicroClip XL can be set to remind users when a bump test is due, and to force a bump test or calibration when one is overdue. A flashing green IntelliFlash light shows that the detector has been bump tested and is monitoring correctly, so supervisors can check compliance at a glance.
For fleets, Honeywell’s IntelliDoX docking station runs automated bump tests and calibration and keeps the records.
We supply bump test gas and regulators matched to the MicroClip’s four sensors. We also provide gas detector calibration with a certificate for each monitor, including units bought elsewhere. Our customer database flags a month in advance when a service is due, so the visit is booked at a time that suits you.
Hydrogen sulphide, carbon monoxide, oxygen and combustible gas. Combustible gas can be shown as % LEL or as % by volume methane.
Honeywell quotes 18 hours typical, with a recharge in under 6 hours. It guarantees runtime for at least a 12 hour shift down to -20°C.
It is rated IP68. Honeywell states this as protection against dust and water for up to 45 minutes at a depth of 1.2 m.
Both are part of the BW MicroClip series, with the same four gases, 18 hour battery and IP68 rating. Honeywell positions the XL as the lower up-front cost option. The X3 adds a new oxygen sensor that extends its expected service lifetime to 5 years.
Yes. It is compatible with Honeywell’s IntelliDoX docking station for automated bump tests and calibration. We supply test gas and regulators for docks and for manual checks.
Tell us how many detectors you need and how your team works, and we will supply the MicroClip XL with test gas to match. Call 01 289 7720 or email info@vistec.ie.