An oxygen depletion monitor measures the oxygen in a room continuously and raises an alarm before the air becomes dangerous to breathe. We design, install, calibrate and service fixed oxygen monitoring systems for laboratories, cryogenic and liquid nitrogen stores, gas cylinder stores and plant rooms across Ireland, and supply portable oxygen monitors for people entering confined spaces.
Nitrogen, argon, helium and carbon dioxide are used every day in labs, hospitals, food production and industry. They are not flammable, and most are not toxic at the levels found in a workroom. The risk is that a leak pushes the oxygen out of the air, and nobody can see, smell or feel it happening.
The Health and Safety Authority’s Code of Practice for Working in Confined Spaces puts the normal oxygen concentration in air at 20.8%. It warns that a relatively small reduction can impair mental ability, that the effects are very rapid with generally no warning to alert the senses, and that very low oxygen concentrations, below 16%, can lead to unconsciousness and death. A person who walks into an oxygen-depleted room often has no chance to walk back out, which is why the alarm has to sound before anyone enters.
Any room where a large volume of inert gas could be released into a limited space should be assessed. Liquefied gases are the biggest risk, because a small spill of liquid nitrogen or argon boils off into a very large volume of gas.
Oxygen monitors normally have two falling alarm levels. A common approach is a first warning at 19.5%, the bottom of the normal range, and a second, evacuate alarm at a lower level such as 18%. The right levels for your site come from your risk assessment, and we agree them with you at installation. Where oxygen itself is stored, a rising alarm can be added too, because the HSA code notes that oxygen enrichment, even by a few percent, considerably increases the risk of fire.
If a room uses carbon dioxide, an oxygen sensor alone is not enough. CO2 can harm people at levels where the oxygen reading has barely changed, so it needs its own sensor. Our CO2 gas detection page covers this.
For a single room we typically fit one or more oxygen sensors wired to a control panel with alarms at the door. The GDS 404 panel takes one to four plug-in sensor channels for oxygen, flammable and toxic gases, with two alarm stages and relay outputs, so oxygen, hydrogen and CO2 can be watched by one system. Where a sensor cannot sit in the room itself, such as a sealed cryostore or a pit, a sampling system such as the GDS 301 draws air from the area to the sensor and monitors for line blockage and pump failure.
Oxygen sensors are usually mounted at breathing height, close to where the inert gas is stored or used. We survey the room, look at the gases, volumes and ventilation, and position the sensors and alarms to suit. Where a lab also has flammable or toxic gases, see our laboratory gas detection page for a full system.
Before anyone enters a tank, pit or vessel, the HSA code says oxygen should normally be tested first, because other gas monitors may only be accurate in a normal oxygen atmosphere. A personal 4-gas monitor such as the Honeywell BW GasAlertMicroClip XL measures oxygen alongside flammable gas, carbon monoxide and hydrogen sulphide, and keeps alarming while the person is inside. See our confined space gas monitors for the range.
Oxygen sensors have a limited life and drift over time, so they need regular calibration with certified test gas. We calibrate fixed and portable oxygen monitors on site, test that the alarms, beacons and relays work, and leave you a calibration certificate for your safety file. Our guide on how often gas detectors should be calibrated explains the intervals.
Normal air contains 20.8% oxygen, according to the HSA’s confined spaces code of practice. The code says any difference from normal should be investigated, that a relatively small reduction can impair mental ability, and that levels below 16% can lead to unconsciousness and death.
Many sites set a first alarm at 19.5%, the bottom of the normal range, and a second alarm lower, often 18%. The levels should come from your own risk assessment, and we agree them with you when we install the system.
Ventilation helps, but it can fail, be switched off or be overwhelmed by a large release such as a liquid nitrogen spill. An oxygen depletion monitor tells you the air is unsafe whatever the cause.
Usually at breathing height and close to where the inert gas is stored or used. The exact position depends on the gas, the room layout and the ventilation, which is why we survey the room first.
Yes. Our engineers calibrate and service oxygen monitoring systems from many manufacturers and record the results for your files.
Tell us which gases you store and the size of the room, and we will recommend sensor positions and alarm levels. Call 01 289 7720 or email info@vistec.ie.